Open systems: The foundation for a new era of BAS

04/01/2013


Dividing the vendor roles

Figure 3: The 4-Tier Open Architecture Model ensures fully transparent interoperability throughout the system. Courtesy: RBCG LLCAn open philosophy sets the stage for vendors to focus on their area of expertise and work with other providers to deliver a complete solution, one that allows building owners to select the right products and vendors for their needs. In this strategy, the integrator role is elevated to oversee the complete project and ensure the building owner's objectives while separating the vendor roles so no one vendor is supplying the entire solution. Many building owners have implemented a multi-tier system architecture that defines these roles, where tier one is the sensor/actuator level; tier two is the field devices, such as the controllers; tier three is the in-building communications and connectivity level including device communication protocols; and tier four is the IT and enterprise infrastructure including user interfaces, both local and remote, data collection, and analysis. By utilizing the four-tier model, a check-and-balance system is put into place that ensures fully transparent interoperability throughout the system.

Embracing IT

The proliferation of IT into nearly every aspect of our daily life illustrates just how efficient and productive we can be with data readily available to us. The BAS industry is no different. As building owners discover what it means to have an open system, they see how intelligent decisions based on usage data positively impact the bottom line. While the definition of "open" may differ from one person to another, the common thread is data and its level of interoperability and accessibility. Couple this with an open protocol that facilitates the access to data across different systems and platforms, and this opens the door for the facility and IT departments to cooperate in the design, implementation, and management of the BAS.

Access to data from anywhere requires even greater support in the base system specification. Tying a BAS system into the facility IP network may seem simple and straightforward, but as soon as the IT department gets involved, a host of issues become exposed as the BAS system encroaches into the IT space. More and more control devices feature native IP access ports, requiring a fixed IP address. The IT department must be aware of and prepared for increased bandwidth utilization and, of particular importance, the security risks.

In 2004, the U.S Army Corps of Engineers published the Unified Facilities Guide Specifications, a definitive specification guideline that identifies building and integration requirements with the ultimate goal of creating "one integrated, multi-vendor system with no future dependence on any one contractor or controls vendor." The guideline encourages competitive bidding at all levels of procurement, and it has been adopted by thousands of installations nationwide. According to Will White, lead project engineer for the U.S. Army Corps of Engineers, "Security on our building systems is critical, and we are actively and aggressively defining the systems and standards to ensure the highest level of security is enabled. This may put an additional burden on the integrators and their vendors, but will enable us to expand our strategy into a fully enterprise-based solution rather than the current, single-premise-based solution."

Efforts within several standards groups are engaged in defining the hardware and software requirement for various levels of security. SGIP 2.0, Inc., is providing a national framework for coordinating all Smart Grid stakeholders in an effort to accelerate standards harmonization and advance the Interoperability of Smart Grid devices and systems, including security issues for tying the smart building into the Smart Grid. Other organizations, including LonMark International, ASHRAE, OASIS, and others, have developed security task forces to begin addressing the specific issues faced by building automation systems.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me