New Ultrasonic Flowmeter Handles Custody Transfer Applications

Krohne's new multichannel ultrasonic flowmeter is accurate and reliable enough to be used for the first time in custody transfer applications. The petroleum industry demands this type of application, but has traditionally had to use turbine meters, which are costly and require cleaning and calibration.

01/01/1998


Krohne's new multichannel ultrasonic flowmeter is accurate and reliable enough to be used for the first time in custody transfer applications. The petroleum industry demands this type of application, but has traditionally had to use turbine meters, which are costly and require cleaning and calibration. Krohne's new Altosonic V is less than one-third the cost of an equivalent turbine meter and requires virtually no cleaning or maintenance because it has no moving parts. The first Altosonic V installations at Shell Oil and Dow Chemical in Germany were successful and Krohne is offering the flowmeter as a standard product. The Altosonic V's flow measuring system consists of a measuring tube with 10 ultrasonic sensors, a field-mounted signal converter, and a flow processor in the control room. The Krohne flowmeter uses a "confuser" device to straighten out disturbed profiles, and five independent measuring lines—with two ultrasonic sensors in each line—to accurately measure the flow profile across the pipe. Extensive signal processing and computing equipment integrate the data to produce measurements, which include not only volumetric flow rate and totalizing, but sound velocity, mass flowrate, temperature, and viscosity.





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Commissioning lighting control systems; 2016 Commissioning Giants; Design high-efficiency hot water systems for hospitals; Evaluating condensation and condensate
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
click me