New AMCA standard for fan efficiency
AMCA Standard 205-10 defines a new energy efficiency classification schema for fans driven by motors at 1/6 HP (125 W) and above.
Michael Ivanovich; Source: Air Movement and Control Association (AMCA) Internati
Arlington Heights, IL, USA---The Air Movement and Control Association International, Inc. ( AMCA International ) announced that AMCA STANDARD 205-10, "Energy Efficiency Classification for Fans," was approved by the AMCA International membership on February 19, 2010.
This standard defines the classification for all fan types designed to be driven by motors of nominal rating 125 W (1/6 hp) and above. The fans can range from the purpose built single fan to series produced fans manufactured in large quantities. This standard applies to the fan and not to the fan system. This standard excludes classification for circulating fans.
This standard may be used by legislative or regulatory bodies for defining the energy efficiency requirements of fans used in specific applications.
The following referenced documents shall be utilized for the application of this document:
ANSI/AMCA Standard 210-07 - Laboratory Methods of Testing Fans for Certified Aerodynamic Performance Ratings.
IEEE 112-2004 - Standard Test Procedure for Polyphase Induction Motors and Generators.
IEEE 114-2001 - Standard Test Procedure for Single Phase Induction Motors.
ISO 5801:2007 - Industrial Fans - Performance Testing Using Standardized Airways.
ISO/DIS 12759 - Fans - Efficiency Classification for Fans.
ISO 13348:2007 - Industrial Fans - Tolerances, Methods of Conversion and Technical Data Presentation.
ISO 13349:2008 - Industrial Fans - Vocabulary and Definitions of Categories.
AMCA Standard 205-10 is available at www.amca.org/store/default.aspx
For background information, read the AMCA white paper, " Fan Efficiency - Facing up to industry challenges ."
For further information please contact:
Joe Brooks , Director of Engineering
AMCA International
30 West University Drive, Arlington Heights, IL 60004
(T) 847-394-0150
(F) 847-253-0088
Case Study Database
Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.
These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.
Click here to visit the Case Study Database and upload your case study.