Microstepping Motor

Hauppauge, N.Y.—Escap P850 high accuracy microstepper incorporates the company's patented disc magnet design, providing repeatable resolution for 100,000 steps per rev with inertial loads. Absolute accuracy is within 3 arc-minutes of true position. Holding torque is 100 oz in with 4.6 A and a 100 W rating.

01/01/1998


Hauppauge, N.Y.— Escap P850 high accuracy microstepper incorporates the company's patented disc magnet design, providing repeatable resolution for 100,000 steps per rev with inertial loads. Absolute accuracy is within 3 arc-minutes of true position. Holding torque is 100 oz in with 4.6 A and a 100 W rating. The motor measures 3.6-in. diameter × 2.0-in. long and weighs 35 oz. The mechanical time constant of 0.5 msec accommodates rapid start-stop, high throughput applications.

Portescap U.S. Inc.





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me