Magnetic Centrifugal Chiller

Johnson Controls Introduces the YORK Magnetic Centrifugal Chiller

08/24/2010


Johnson Controls introduces the YORK Magnetic Centrifugal Chiller (YMC²), which offers superior efficiency and sound performance.

 

Magnetic-bearing technology is utilized to eliminate mechanical-contact losses in the driveline. The OptiSpeed variable-speed drive has been improved, and efficiency of the evaporator has been enhanced with an advanced “falling-film” design. In addition, the efficiency features have been retained, including the optimized centrifugal compressor that takes advantage of low-temperature cooling-tower water to save energy.

 

Magnetic-bearing technology eliminates nearly all driveline vibration, and the YORK OptiSound control further reduces noise at off-design conditions. As a result, the YMC2 chiller operates at a maximum of 73 dBA at full-load standard conditions, per AHRI-575. The human ear perceives the YMC² chiller as about half as loud as other magnetic-bearing chillers.

 

The YMC² chiller features a sustainable design that uses refrigerant HFC-134a, which has zero ozone-depletion potential. The 10-% efficiency improvement dramatically reduces indirect global warming caused by greenhouse-gas emissions generated by electric utilities. In addition, 57% fewer refrigerant-piping connections drastically reduce the potential for direct global warming caused by refrigerant leakage.

 

The YMC² chiller also increases uptime and reduces maintenance costs. The magnetic-bearing drive has fewer moving parts and eliminates the oil-lubrication system. The driveline is field-serviceable, which means a back-up driveline is not needed. The chiller’s permanent-magnet motor has an inherently longer life than traditional motors, and the OptiSpeed drive’s soft-start sequence further extends motor life.   



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity
About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.