Machine safety: Does ISO 13849-1: 2006 weight severity, frequency, and probability equally?

New quantitative requirements for designing safety-related parts of the control system (SRP/CS) have created many discussions. Even with new requirements from ISO 13849-1, this updated standard begins with the same old qualitative approach to determine the “goal” (Performance Level required- PLr) for any safety function, asking about severity, frequency, and probability.

05/20/2013


New quantitative requirements for designing safety-related parts of the control system (SRP/CS) have created many related discussions about machine safety.  Yet, even with these new requirements from ISO 13849-1, this updated standard begins with the same old qualitative approach to determine the “goal” (Performance Level required- PLr) for any safety function. The same three questions are still asked; Severity, Frequency and Probability.

 

EN954-1 came out in 1996 with an amazing way to put more teeth into determining a hazard level and related mitigation solution for any recognized hazard. In so doing we had to analyze each hazard by evaluating the related potential injury by severity, frequency, and probability according to the graph below.

Two safety standards EN954-1 in 1996 and the 2006 ISO 13849-1 help with determining hazards and potential injury by looking at severity, frequency, and probability. Courtesy: Control Engineering Machine Safety blogTen years later in 2006 ISO 13849-1 was updated and released introducing Performance Levels and the requirement to develop the PLr, which I call the goal. To develop the PLr, we again use the qualitative approach by evaluating the related potential injury by severity, frequency, and probability also shown in the graph. There’s a whole lot more we could get into here but let’s keep it focused at the three questions.

What was the criteria for approaching these three questions in their order of severity, frequency and probability? Is severity weighted the most because it’s the first question? Such as; S = 50%, F = 30% and P = 20%? Or is probability asked last because of its greater impact? Such as; S = 25%, F = 35% and P = 40%? Or, does it matter at all? Can all three questions be equally interchanged?

J.B. Titus, CFSE

Can anybody provide some insight and background? Has this presented you with any new perspectives? Add your comments or thoughts to the discussion by submitting your ideas, experiences, and challenges in the comments section below.

 

Related articles:

Machine safety: Confusion amuck, quantitative circuit design versus qualitative risk assessment.

Machine Safety: Can end user companies comply with ISO 13849-1: 2006 without design engineering resources?

Machine Safety – incorporating “Functional Safety” as part of your machine safety plan – Part 1

 

Contact: http://www.jbtitus.com for “Solutions for Machine Safety”.



Anonymous , 05/20/13 12:41 PM:

The way I see it the starting point in the 13849-1 diagram is 50%. We go up or down from there. If you treat the severity as 25% and the two other decisions as 12.5% each, you end up with the five levels representing 0, 25%, 50%, 75% and 100%. Assuming that's what was intended, the F and P decisions can be treated as interchangeable, but S comes first. I don't know much about the rationale behind the decision process. The standard doesn't do a good job of explaining how the decision process relates to the risk reduction it shows in Figure 2.
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me