Machine Safety: Actuator controls versus machine actuators

Why is knowing the difference between a machine actuator versus an actuator control important? The hazard on a machine is what’s really important to reducing risk! Understanding two standards-based definitions can help.

06/12/2013


Why is knowing the difference between a machine actuator versus an actuator control important? The hazard on a machine is what’s really important to reducing risk! 

What is the hazard? Motion caused by a machine actuator can be a hazard to an operator, maintenance technician, set-up engineer, or clean-up personnel, to mention a few. However, the power (electrical, hydraulic, pneumatic, etc.) applied to the actuator control also can be a hazard to the same personnel. So, is looking at the hazard the best way to understand these terms? 

Perhaps some definitions of these two terms may help clear up the confusion. Several international and domestic standards define:

  1. An actuator control as an operator control device used to initiate or maintain machine motion or other machine function(s). Some examples given include; two-hand control, treadle bar, foot control, inching button, e-stop device, etc.
  2. A machine actuator as a power mechanism used to cause motion of a machine. Some examples given include; air cylinder, motor starter, hydraulic valve, etc.

That said (and not to add more confusion) the machine safety standards also explain that a PSD (presence sensing device) device is an example of an actuator control. An example is when the robot arm retracts from a light curtain field initiating a signal to the machine control system to automatically cycle the machine. Or, when a “safe drive” automatically detects a fault and causes a Cat 1 machine stop. Where’s the operator in these examples? 

Regarding machine actuators, I’ve also seen the metal rod inside an operator control device described as an actuator because it causes the contact(s) to open and remove power. Therefore, can a machine actuator also cause the stopping of a machine motion as well as causing machine motion? What about the friction clutch in a mechanical power press? Is this device a machine actuator since it either causes or stops motion and is powered via electric, hydraulic, pneumatic or spring type energy? 

I believe by now the answer might be as clear as mud. So, what’s the point? It’s my opinion that this discussion is a good example where industry experts can help interpret the intent and requirements of machine safety industry standards. After all, has anyone ever seen a prescriptive Standard for compliance?

Has this presented you with any new perspectives? Add your comments or thoughts to the discussion by submitting your ideas, experiences, and challenges in the comments section below. 

J.B. Titus, CFSE

Related articles:

Inside Machines: Does adopting ISO 13849-1:2006 change the U.S. model for compliance and enforcement?

Machine Safety – does OSHA reference consensus standards for compliance?

Machine Safety: Is OSHA okay with my 'acceptable' risk mitigation?

Contact: http://www.jbtitus.com for “Solutions for Machine Safety”.



Jummah , Non-US/Not Applicable, Saudi Arabia, 06/14/13 10:07 AM:

As far as safety concerns, those who works on resturants, where they are only or not recieving any taining on HMI, they always pay the price. One day I was taking a meal in some resturant, I saw a guy used to serve me, was holding his arm to his neck by medical band, when I asked, he told me, that 2 of his fingers were minced at the meat machine. That is a painful accedent, could it be any way for the control system to avoid this or at least minimized it.

thankyou.
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me