Inverter scroll compressor

Danfoss’ VZH inverter scroll compressor uses a brushless interior permanent magnet (IPM) design and its variable speed technology provides infinite and smooth capacity modulation.

06/04/2013


Danfoss’ VZH inverter scroll compressor uses a brushless interior permanent magnet (IPM) design and its variable spreed technology provides infinite and smooth capacity modulation. Courtesy: DanfossDanfoss’ VZH inverter scroll compressor uses a brushless interior permanent magnet (IPM) design and is optimized for different pressure ratios to deliver energy savings of more than 30% when compared to a unit equipped with a fixed or mechanically modulating compressor. In addition, the variable speed technology provides infinite and smooth capacity modulation, delivering precise temperature control within 0.1 F of the setpoint. This is ideal for applications that require precise temperature and humidity control, including IT equipment, industrial processes, museums, and libraries. With cooling capacities ranging from 13 to 26 TR, the VZH provides the largest cooling capacity with a single variable speed hermetic scroll compressor and the widest variable speed compressor range in the market for air-conditioning applications. A 4:1 modulation ratio allows the VZH inverter scroll compressor to modulate from 25 to 100 rps for greater savings. Pre-equipped tandem capability extends the cooling capacity to 52 TR and a 12% to 100% stepless modulation for a variety of demanding applications where low part-loads are needed. The VZH is available with optimization at two pressure ratios for either chiller or rooftop applications. 

Danfoss 

www.danfoss.us



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Commissioning lighting control systems; 2016 Commissioning Giants; Design high-efficiency hot water systems for hospitals; Evaluating condensation and condensate
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
click me