HVAC Consideration For Schools


A school district’s biggest expense after payroll is its utility bill. Because the HVAC system is a major component of a school’s utility bill, careful evaluation of a school’s HVAC requirements and equipment options can help administrators save money while actually improving learning productivity.

Every school is different, so there is no one HVAC solution for all schools. Instead, there is a “best” solution for each individual school—chosen from careful evaluation—that maintains the highest possible indoor air quality at the lowest possible energy costs. A well-designed HVAC system maintains space temperature and humidity conditions, as well as minimum outdoor air amounts, economically and efficiently. ASHRAE standard 62.1-1999 recommends that each person in a classroom receive 15 cu. ft. per minute of fresh air, and a classroom with 30 people requires a ventilation rate of about 450 cfm. Factor in a school’s age, size, construction—such as walls, lights, doors and windows—zone requirements and the climate where the school is located, and it’s easy to see why schools present unique challenges for meeting HVAC requirements. The key is knowing how to balance all the elements of the equation.

Zone requirements are particularly important for schools. Each school has several different zones, each with specific needs for heating, cooling and ventilating. Classrooms generally have high ventilation requirements, three times that of an office, but only when occupied. Dedicated classrooms, such as science and computer areas, require extra cooling or ventilation. Administrative areas require lower heating and cooling, but are occupied over longer hours. Cafeterias need special ventilation for food preparation, and gymnasiums, occupied during the day and evening, have a range of load requirements and scheduling demands.

A variety of types of equipment and configurations are available to meet the requirements for schools.

Decentralized systems (such as AAFâ -HermanNelson â unit ventilators from McQuay, water-source heat pumps and fan coil units) provide heating, cooling and conditioning, i.e., humidity control, to individual classrooms or zones. The advantage of a decentralized system is that it can provide cooling to one space and heating to another. Scheduling can be zone specific to allow for increased operating cost savings. Ideal for new or existing buildings, decentralized systems are easy to service and can rival the most advanced built-up systems for energy efficiency. A disadvantage is that the equipment resides in or near occupied spaces, so maintenance needs to be scheduled when the affected zone is not occupied.

Unit ventilators . Introduced in 1917, AAF-HermanNelson unit ventilators are the only system designed exclusively for schools to provide up to 100% outdoor air directly into a classroom. These unit ventilators have kept pace with HVAC technology and now include sophisticated controls and enhanced design to make them quiet, energy efficient and cost-effective. Their sturdy, flexible construction allows them to withstand years of classroom activity. In general, unit ventilators can provide cooling, heating and fresh air, and can be positioned on a classroom wall or ceiling.

Water-source heat pumps . Versatility makes water-source heat pumps a good choice for medium and large schools, schools with large internal zones and retrofit applications. Rather than rely on a central chiller plant for cooling, heat pumps move energy around the school in water rather than air by adding and subtracting energy from a common loop. Because of the loop system, heat collected from cooled zones can heat zones that require heating. Heat pumps don’t require insulation, which reduces first cost. Unlike unit ventilators, they require outdoor air systems to bring in enough fresh air to meet ventilation requirements.

Fan coils . Like water-source heat pumps, fan coils distribute energy through piping rather than ductwork. Fan coils require a chiller and boiler plant, as well as a dedicated outside air system. Because they do not require compressors, fan coils are quiet.

Outdoor air ventilation systems . With the exception of unit ventilators, decentralized systems, such as water-source heat pumps and fan coils, require dedicated outdoor air systems to bring in enough fresh air to meet the ventilation requirement. Outdoor air systems can be expensive to operate, so they must be carefully designed. Outdoor air must be heated, cooled and conditioned, depending on season and climate, presenting a significant utility bill to administrators. A basic gas heat, air-conditioned cooling system can cost over $30,000 per year to operate - a price that can be halved with a good design and proper equipment. Energy recovery systems that capture and “recycle” conditioned air and return some of it to classrooms - up to 50% - can also significantly improve operating efficiency.

Central systems

Unlike decentralized systems, which control individual zones, a central system controls many zones, such as a block of classrooms, the administrative area or the gymnasium. These all-air systems condition air in a remote location, such as a mechanical room or on a roof, and distribute it through ductwork to the occupied spaces. Remote equipment can be quieter and

easier to service because it does not reside in occupied spaces. However, because they serve larger areas, redundancy should be carefully considered in the design of the system in case it experiences downtime.

Central systems can be complicated to design and install, commission and operate. Ductwork can be large and difficult to fit in a ceiling plenum. Keys to successful operation are BAS, computerized controls that monitor and operate heating and cooling throughout a building. Central systems include air handling units and chiller plants, rooftop systems and vertical self-contained systems.

Air-handling units . The building block for central systems, air-handling units do just what their name implies: they bring in air from the outside, condition it with heating or cooling, and distribute it throughout the building. Air-handling units often work in tandem with chillers to provide chilled-water cooling, a solution that is affordable and energy efficient. Indoor air-handling units are extremely flexible, and a variety of sizes and components can be selected to meet the specific space limitations and performance requirements of virtually any application. Air-handling units can also be located on a rooftop to save valuable indoor space. Low sound attenuation, easy servicing and efficient operation - especially when energy recovery wheels or plates are incorporated - are all hallmarks of McQuay air-handling units.

Chillers . Chiller plants, either air- or water-cooled, are used in combination with several types of HVAC systems, including unit ventilators, fan coils and air-handling units. Chilled water for cooling provides efficient operation, especially in larger schools. A natural choice for new construction and large schools, chillers can also be installed with an existing system, especially when a school is adding air conditioning for the first time. Because they can potentially consume large amounts of energy, chillers must be chosen for their performance balanced with first cost and serviceability.

Applied rooftop systems . Applied rooftop systems, such as McQuay RoofPakÔ systems, offer much the same component flexibility as air handlers, and they incorporate a condensing section for self-contained cooling. This eliminates the need for a chiller plant. Low sound attenuation, easy servicing and efficient operation - especially when energy recovery wheels and DesignFlow Ô Outdoor Air Measurement are incorporated - are also benefits of McQuay applied rooftop systems.

Indoor vertical self-contained systems . Installed in mechanical rooms, indoor vertical self-contained systems are air-conditioning units with water-cooled condensers. No chiller plant is required and the equipment is easily accessible for service without disrupting students. Self-contained units eliminate the need for insulated chilled water piping, pumps and large mechanical rooms.

HVAC controls . No matter what HVAC system is chosen for a school, the system will require computer controls to monitor and adjust heating and ventilation rates. Systems can be designed for remote monitoring, from the administrative office, or for individual classroom temperature control. Sophisticated systems, such as McQuay MicroTech II ä Controls, are interoperable with a district’s entire BAS. The key benefit of controls is their ability to reduce operating costs. Knowing how well a system is operating allows the facility manager to make adjustments to improve performance and lower energy consumption.

In all, the best HVAC system is the one that best fits a school’s requirements, both in terms of budget and performance. Each school has specific needs that can be met with the right system and design. Choosing equipment designed especially for a particular school will provide efficient, effective operation from first cost through the life cycle of the product.





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
High-performance buildings; Building envelope and integration; Electrical, HVAC system integration; Smoke control systems; Using BAS for M&V
Pressure piping systems: Designing with ASME; Lab ventilation; Lighting controls; Reduce energy use with VFDs
Smoke control: Designing for proper ventilation; Smart Grid Standard 201P; Commissioning HVAC systems; Boilers and boiler systems
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Protecting standby generators for mission critical facilities; Selecting energy-efficient transformers; Integrating power monitoring systems; Mitigating harmonics in electrical systems
Commissioning electrical systems in mission critical facilities; Anticipating the Smart Grid; Mitigating arc flash hazards in medium-voltage switchgear; Comparing generator sizing software
Integrating BAS, electrical systems; Electrical system flexibility; Hospital electrical distribution; Electrical system grounding
Cannon Design’s blog is a place for the many voices of the firm to share thoughts and news related to current projects...
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.