Guide to optimizing fuel combustion

ABB 12-page guide on efficiency, environmental impact.

06/30/2011


This 12-page guide from ABB provides basic information for optimizing combustion to improve efficiency, lower environmental impact, and reduce downtime. The guide, available as a PDF file, notes that users can apply this knowledge to: process heaters for increased throughput, waste incinerators for waste throughput and environmental impact, and steam raising for power generation and various industries where fuel efficiency is important. For this discussion the guide defines combustion as the oxidation of a fuel, mainly hydrocarbon, for the purpose of producing useful heat. It goes on to cover the optimum ratios of air and fuel to maximize efficiency for reduced operating costs and good emissions control. The guide continues with an explanation of the role of in-place zirconium oxygen sensors in the furnace and flue. It explains how the sensors work and provides a great deal of application information for interpreting sensor readings.

www.abb.com



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
click me