Grand Valley State University Science Lab, Classroom, and Office Building

New construction; Grand Valley State University Science Lab, Classroom, and Office Building; Fishbeck, Thompson, Carr and Huber Inc.

08/15/2013


This image shows the rendering of the Grand Valley State University project. Courtesy: Fishbeck, Thompson, Carr & HuberEngineering firm: Fishbeck, Thompson, Carr & Huber Inc.
2013 MEP Giants rank:
99
Project:
Grand Valley State University Science Lab, Classroom, and Office Building
Address:
Allendale, Mich., United States
Building type:
School (college, university)
Project type:
New construction
Engineering services:
Automation & Controls, Electrical/Power, HVAC, Lighting
Project timeline:
September 2011 to May 2015
Engineering services budget:
N/A
MEP budget: $964,304

Challenges and solutions

Understanding that lab buildings are typically large energy consumers, FTC&H tailored the mechanical design to utilize energy efficient systems and equipment. Some of the strategies included ventilation control through an active contaminant monitoring system, heat recovery/exchange between exhaust and fresh airstreams, occupancy control of terminal unit zone controls, and use of an auxiliary heat recovery chiller to efficiently handle simultaneous heating and cooling loads within the building.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Emergency lighting; NFPA 3 and 4; Integrated building systems; Smart lighting, HVAC design
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me