SEARCH Archives
Loading
Sponsored by:

Fixed Capacitors for Low Voltage Power Factor Correction

StacoVAR fixed capacitors for power factor correction and harmonic compensation.

10/05/2010


Staco Energy Products introduces its second generation of StacoVAR fixed capacitors for power factor correction and harmonic compensation. These standard units are available from 2.5 kVAR to 400 kVAR as economical, fixed motor load (ML) type capacitor assemblies.

Equipped with fusing and blown-fuse indicator lights as standard, StacoVAR fixed capacitor assemblies are idea for indoor or outdoor use with voltages from 240 Vac to 600 Vac. These complete assemblies are UL 508A listed, c-UL, and available from stock or with fast delivery times. They are ideal for improving power factor where induction motors are located, including manufacturing facilities, food and beverage processing, warehousing and distribution centers, water and wastewater treatment plants, and more. 

These metalized polypropylene capacitors are self-healing to prevent permanent dielectric breakdown. Each capacitor is designed for a long service life over a wide temperature range. They withstand the most demanding conditions, including harmonics of up to 10% THD. Pressure sensitive circuit interruption within the capacitor allows the units to be safely removed from service under heavy fault conditions while maintaining case integrity. External discharge resistors allow voltage to be reduced to 50 volts or less in one minute. 

StacoVAR ML capacitors are housed in a rugged metal enclosure and include a terminal type power line connection for quick, simple installation. Available enclosures include NEMA 1, 12, or 3R ratings. They can be mounted either vertically or horizontally to meet a variety of application needs. Current limiting fuses are rated at 165% of the rated current. Three blown fuse indicator lights provide illumination for fuse replacement.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity
About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.