SEARCH Archives
Loading
Sponsored by:

FEMA Fabricated Steel Grille

09/16/2010


Greenheck’s new FEMA Model FSG-801 fabricated steel grille protects exterior wall penetrations on FEMA 361 or 320 compliant storm shelters or safe rooms. Fabricated of 0.25-in thick hot-rolled steel and designed with inverted V-style blades, Model FSG-801 allows high free area and very little airflow resistance while providing maximum protection against extremely high wind-load and wind-borne debris. Most frequently installed in front of louvers on the building’s exterior, the FEMA grille can be installed in a cantilevered position or in a flush/recessed mount configuration. Model FSG-801 has a UL Listed windstorm rated assembly, can withstand wind-loads up to 248 psf, and complies with ICC500 for large missile impact, which simulates a 15 lb. 2 x 4 traveling at 100 MPH.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity
About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.