Excellence in Automation: System Integrator of the Year Awards

12/16/2013


Page 2 of 2

This posted version of this article includes more information about each winning system integrator below, expanding upon information provided in the print and digital edition article.

Cogent Industrial Technologies Ltd.

Year Founded: 2005

Annual Revenue: $1-5 million

13091 Vanier Place - Unit 180

Richmond, BC V6V 2J1 Canada

www.cogentind.com 

Industries Served: automation/control, building automation, metals, power, processing, utilities, water/wastewater, wood products, pulp/paper, energy—general, mining/minerals

Areas Served: Canada; USA in DE, MD, VA, WV, NC, SC, GA, FL; Europe; South America

Engineering Specialties: automation—general, building automation, data collection/reporting, data processing/management, electrical engineering, energy management, human-machine interfaces, information systems, installation/start-up, international projects, networking/communications, PLCs, process control, project management, safety/security systems, SCADA, supervisory control, systems engineering, Web technology, factory automation, project planning, simulation/modeling, training/education, wireless, industrial engineering, C/C++, CEMS, MES, plant performance monitoring

Product Experience, Allen-Bradley, Rockwell Automation, Rockwell Software, Siemens, Wonderware, Cisco Systems, Citect, Microsoft, OSIsoft, AspenTech, Schneider Electric, Pilz, Rittal, Sick Optics, Triconex, Weidmuller, Yokogawa

Corporate Affiliations: Not applicable

Professional Affiliations: CSIA

Corporate Resume: Cogent Industrial Technologies provides Electrical, Controls and IT system design and integration services to industrial operations and facilities. From greenfield to modernization projects, Cogent's services and solutions deliver a safe, reliable and efficient operation and empower your people to manage and improve operational effectiveness.

Insist Avtomatika, LLC

Year Founded: 1993

Annual Revenue: $10-25 million

18/1a, Marx. St.

Omsk, 644042 Russia

www.industrialsystems.ru/en 

Industries Served: oil/gas, chemical/petrochemical, communications, metals, petroleum, tires, utilities, food/beverage, pipelines, power

Areas Served: Europe, Middle East

Engineering Specialties: automation—general, control panels, distributed control systems (DCS), process control, project management, data processing/management, designs/specifications, human-machine interfaces, installation/start-up, maintenance/repair, MES, networking/communications, PLCs, SCADA, Web technology, advanced control, CAD/CAM/documentation, ERP, information systems, turnkey systems, wireless, training/education.

Product Experience: Allen-Bradley, Emerson Process Management, OSIsoft, Rockwell Automation, Wonderware, Pepperl + Fuchs, Phoenix Contact, Rittal, ABB, AutomationDirect, Control Microsystems, GE Intelligent Platforms, Microsoft, Omron Electronics, Oracle, Schneider Electric, Weidmuller, Mettler Toledo, Siemens, Yokogawa

Corporate Affiliations: Emerson Process Management, Microsoft, OSIsoft, Rockwell Automation, Siemens, Wonderware

Professional Affiliations: CSIA certified, CSIA, ISA Automation Alliance Group (AAG)

Corporate Resume: Industrial Automation Systems (Insist Avtomatika LLC) is an engineering company offering a full scope of services for development and implementation of automation solutions and information systems for customers in oil and gas, metallurgy, power and other industries. Since its foundation in 1993 Insist Avtomatika has been working as a process automation contractor on large Russian oil and gas fields development projects. Among the company's customers are major Russian and international oil and gas companies. Insist Avtomatika has headquarters with main production facilities located in Omsk (Russia) and representative offices in Moscow (Russia), Vladivostok (Russia), Houston, TX (USA), and Sharjah (UAE). Insist Avtomatika is the only Russian member of the Control System Integrators Association (CSIA).

Wood Group Mustang

Year Founded: 1987

Annual Revenue: Over $50 million

16001 Park Ten Place

Houston, TX 77084 United States

www.mustangeng.com/BusinessUnits/AutomationandControl 

Industries Served: automation/control, chemical/petrochemical, offshore, oil/gas, petroleum, communications, environmental, mining/minerals, pipelines, power, biotechnology, cogeneration, consumer products, engineering/construction, pulp/paper, specialty chemicals, aluminum, automotive, discrete manufacturing, energy—general, food/beverage, manufacturing—general, pharmaceuticals, processing, textiles/fibers, utilities

Areas Served: USA: AK, WA, OR, CA, HI; AR, LA, OK, TX; DE, MD, VA, WV, NC, SC, GA, FL; KY, TN, AL, MS, ME, NH, VT, MA, RI, CT; MN, IA, MO, ND, SD, NE, KS; MT, ID, WY, CO, NM, AZ, UT, NV; NY, NJ, PA; OH, IN, IL ,MI, WI; Canada; Central America; Middle East; South America; Asia; Caribbean; Europe; European Union

Engineering Specialties: automation—general, distributed control systems (DCS), human-machine interfaces, installation/start-up, process control, project management, project planning, safety/security systems, 21 CFR Part 11, advanced control, data collection/reporting, information systems, instrumentation/data acquisition, international projects, MES, regulatory compliance, SCADA, supervisory control, blending, CAD/CAM/documentation, combustion engineering, control panels, data processing/management, designs/specifications, energy management, environmental engineering, financial analysis, manufacturing planning, networking/communications, PLCs, process engineering, signal process/conditioning, simulation/modeling, systems engineering, Web technology, wireless, analyzer systems, CEMS chemical engineering, civil/structural engineering, computer software, construction/architecture, discrete control, enclosures, ERP, field service, petroleum engineering

Product Experience: Allen-Bradley, AspenTech, Autodesk, Bently Nevada, Emerson Industrial Automation, Emerson Process Management, Foxboro, Honeywell, OSIsoft, Rockwell Automation, Rockwell Software, Triconex, Wonderware, ABB, Cisco Systems, Citect, Dell, Endress + Hauser, GE Intelligent Platforms, Invensys, MatrikonOPC, Oracle, Pepperl + Fuchs, Schneider Electric, Siemens, Yokogawa, Eurotherm, IBM, Iconics, Microsoft, Toshiba, Weidmuller

Corporate Affiliations: Allen-Bradley, Honeywell, ABB, AspenTech, Bently Nevada, Cisco Systems, Foxboro, GE Intelligent Platforms, Rockwell Automation, Rockwell Software, Wonderware, Yokogawa, Emerson Process Management, Invensys, Microsoft, OSIsoft, Triconex, Weidmuller

Professional Affiliations, Control Engineering System Integrator Hall of Fame, CSIA, CSIA certified, ISA, ACS, AIChE, API, ASME, AWMA a, IMS/IEEE

Corporate Resume: Wood Group Mustang is a leader in providing engineering, specification, integration and implementation of control, automation, and information systems to the process industries. Wood Group Mustang delivers projects to your schedule, managing multiple and diverse technologies, automation, maintenance and business system integration and lifecycle costs. The company's vendor-independent approach allows them to objectively assist in the selection process of the major controls hardware and software in order to maximize your facility’s operating efficiency, reliability, and productivity. Also, as part of a large engineering company, they have the internal knowledge and resources to offer clients a single-source solution, from concept to commissioning and startup.

-

Link to video advice from these representatives of these three System Integrator of the Year winners.

-


<< First < Previous 1 2 Next > Last >>

D. , , 12/26/13 09:36 PM:

Through value and re-engineering an efficient integrated system can be achieved.
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
40 Under 40; Performance-based design; Clean agent fire suppression; NFPA 92; Future of commissioning; Successful project management principles
BIM coordination; MEP projects; NFPA 13; Data center Q&A; Networked lighting controls; 2017 Product of the Year finalists
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me