SEARCH Archives
Loading
Sponsored by:

Dual voltage SCR dc motor speed control, up to 2 hp motors

The OMDC-250 Series variable speed dc control offers flexibility, reliability, and value, according to Omega Engineering. The general purpose control is rated and tested to 2 horsepower.

08/12/2010


OMDC-253G-200E variable speed dc control is used to control speed in Omega's wire processing.The OMDC-250 Series variable speed dc control offers flexibility, reliability, and value, according to Omega Engineering. The general purpose control, rated and tested to 2 horsepower, also provides:

  • Adjustable IR compensation;
  • Line voltage compensation;
  • 5 kΩ speed potentiometer;
  • 150% overload capacity;
  • Transient voltage protection;
  • Voltage following mode or dc tachometer follower by supplying ungrounded analog input signal (0 to 12 V dc);
  • dc tachometer feedback;
  • Inhibit circuit permits start and stop without breaking ac lines;
  • Remote start/stop via pot circuit or inhibit circuit; and
  • Shunt field supply provided specifications
    Temperature: -10 to 45 °C (14 to 113 °F)
    AC Input Voltage: ±10% rated line voltage
    Input Frequency: 50/60 Hz
    Dimensions: 97 W x 140 H x 89 mm D (3.8 x 5.5 x 3.5-in.)
    Weight: 284 g (10 oz).

When using the -29 option (FWD-OFF-REV switch), care must be taken to stop the motor completely before switching direction. Damage to the drive can result from switching direction at speed.

Learn more about the OMDC-250 Series variable speed dc control from Omega Engineering via www.omega.com.

Also see the Control Engineering Machine Control channel and the

Motors and Drives new products page.

- Edited by Mark T. Hoske, Control Engineering, www.controleng.com, CFE Media.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity
About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.