BACnet standard improves alarm handling

Changes to the newly published BACnet standard from ASHRAE will encourage smart lighting controls and other building automation control systems.

03/15/2013


ANSI/ASHRAE Standard 135-2012, BACnet – A Data Communication Protocol for Building Automation and Control Networks, allows building equipment and systems manufactured by different companies to work together.

The new standard is being published due to the wide-reaching changes in alarming functionality made by addendum af to Standard 135-2010. This edition of the standard also includes recently adopted changes for the lighting industry.

Addendum af provides improvements to alarm handling in BACnet including: Improved fault handling, temporary alarm recipient subscriptions, improvements in scalability of alarm distribution and simplifications in alarm distribution to support less complex products.

Addendum af contains 32 parts. Changes include separating the detection of fault conditions from intrinsic reporting and making sure event reporting property descriptions are consistent. Other addendums include changing the description of the reliability property and improving fault detection in event enrollment objects and the specification of event reporting.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Designing for energy efficiency; Understanding and applying NFPA 101 for mission critical facilities; Integrating commissioning and testing for fire alarm systems; Optimizing unitary pumping solutions
Economics of HVAC systems; NFPA 110-2016; Designing and choosing modular data centers
Combined heat and power; Assessing replacement of electrical systems; Energy codes and lighting; Salary Survey; Fan efficiency
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
Driving motor efficiency; Preventing Arc Flash in mission critical facilities; Integrating alternative power and existing electrical systems
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
click me