SEARCH Archives
Loading
Sponsored by:

BACnet controller

Wago Corp.’s 750-830 BACnet Controller offers simplified system-wide integration/configuration.

09/27/2012


Wago Corp.’s 750-830 BACnet Controller. Courtesy: WagoWago Corp.’s 750-830 BACnet Controller features innovative software with extended functionality and simplified system-wide integration/configuration. New functions include text-messaging support (plain text on the management level) to provide facility managers with alerts. Features—“Loop” (control algorithms), “Event Enrollment” (alarm queries) object types, and creation of a “Trend Log” and “Calendar” dynamic objects during run time—require no system reboot or external integrator. A device manager eases object configuration and allows tabular data processing. The 750-830 BACnet Controller's native operation, which automatically generates a BACnet object for each standard I/O signal, has also received significant enhancements. I/O modules can now be subsequently added or removed from a fieldbus node without shifting object entities. Physical values are now scaled directly in the form of analog input/output objects. Additional analog value objects are no longer required in CoDeSys, simplifying mass-processing of data points and integration into external systems. 

Wago Corp. 

www.wago.us



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity
About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.