ASHRAE Handbook offers guidance on variable refrigerant flow

The 2012 ASHRAE Handbook features a chapter on new guidance for variable refrigerant flow (VRF) systems.

06/05/2012


The 2012 ASHRAE Handbook – HVAC Systems and Equipment discusses systems and the equipment that comprises these systems, including features and differences. It is designed to help system designers and building operators select and use equipment. It contains 52 chapters.

Chapter 18, Variable Refrigerant Flow (VRF) Systems, describes these systems, their components, and applicable standards in detail, and includes a system design example and important guidance on costs, controls, and safety. In previous volumes, VRF was covered in the unitary products section.

“This new chapter covers the A to Z of variable refrigerant flow – from application of VRF to understanding how VRF works and from analyzing a building load in terms of VRF to zoning with VRF,” Paul Doppel, chair of ASHRAE’s technical committee on variable refrigerant flow that wrote the chapter, said. “The chapter offers an excellent overview of VRF technology, including discussion about 2-pipe and 3-pipe system performance during heating operations.”

The chapter also includes a section that lays out a process for designing with VRF including a load analysis, as well as discussions regarding system expansion and designing systems to meet ASHRAE standard requirements.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity
About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.