ASHRAE announces Student Design Competition winners

ASHRAE’s 2011 Student Design Competition winners include students from the United States and China.

08/24/2011


ASHRAE’s 2011 Student Design Competition drilled students on their knowledge of HVAC/R system selection and design as well as integrated building design to encourage practical design.

This year’s competition featured a mock design of the Drake Well Museum located in Titusville, Pa., the site where Edwin L. Drake drilled the world's first oil well in 1859 and launched the modern petroleum industry. Among the 20-plus entries from around the world, three were awarded first place in the three categories that the Competition offers. First place in HVAC System Design is awarded to Holly Brink, Michael Crabb, James Dougherty Jr., Andrew Gilliam and Gina Halbom of the University of Nebraska. Their faculty advisor is Grenville Yuil, Ph.D.

After analyzing three system designs, the team chose a variable air volume system with heat and ground cooled geothermal heat recovery chiller/heater. The higher initial cost of the system is countered by its overall efficiency, low maintenance and federal tax incentives. The final system design outperformed baseline case energy by 33 percent.

First place in HVAC System Selection is awarded to Lynn Gualtieri, Evan Oda, Kristin Porter, Navid Saiidnia, Jeffrey Wong and Cameron Young of California Polytechnic State University, San Luis Obispo, Calif. Their faculty advisor is Jesse Maddren.

The team chose a water-source variable refrigerant volume (VRV) system, which includes a ground-source water loop, a dedicated outdoor air (DOA) unit and humidifiers, as well as addition of a solar array. The VRV is split into two systems: a constant environmental control system for the collections areas and galleries, and a standard environmental control system for the offices, education center, auditorium and lobby. In each separate system the latent and sensible load were decoupled – the VRV fan coils handle the sensible load while a DOA unit with humidifiers handles the latent load.

This setup allows the entire VRV system to control the indoor environment to specified conditions. The advantage of having two systems is the standard environmental control system can be completely shut off during non-occupied hours, which saves energy when compared to running a single large DOA at very low part load.

First place in Integrated Sustainable Building Design is awarded to Te Qi, Zhang Qiqi and Chen Yuanyi of Tianjin University, China. Their advisors are Liu Junjie and Long Zhengwei.

The students integrated a ground-source heat pump for space conditioning and domestic hot water; optimized the fenestration (quantity, location and type of windows); added a solar heat storage system with thermal solar collector; changed the building orientation to 5 degrees south to the east for more efficient orientation; and used thermal mass in walls to reduce heating and cooling loads.

The team had to build detailed energy simulation models, and they demonstrated they understood synergy and compromise when they noted “As for modeling and simulation research, it is essential to integrate different modeling strategy to evaluate a building performance. Through this process, we find sometimes they contradict each other. However, they sometimes support each other.”

The competition recognizes outstanding student design projects, encourages undergraduate students to become involved in the profession, promotes teamwork and allows students to apply their knowledge of practical design.

The first place teams are given 10-15 minutes to present their projects at the 2012 Winter Conference in Chicago, Jan. 21-25.

Details of the winning presentations can be found here.

- Edited by Chris Vavra, Consulting-Specifying Engineer, www.csemag.com 



Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
2017 MEP Giants; Mergers and acquisitions report; ASHRAE 62.1; LEED v4 updates and tips; Understanding overcurrent protection
Integrating electrical and HVAC for energy efficiency; Mixed-use buildings; ASHRAE 90.4; Wireless fire alarms assessment and challenges
Integrated building networks, NFPA 99, recover waste heat, chilled water systems, Internet of Things, BAS controls
Transformers; Electrical system design; Selecting and sizing transformers; Grounded and ungrounded system design, Paralleling generator systems
Commissioning electrical systems; Designing emergency and standby generator systems; VFDs in high-performance buildings
Tying a microgrid to the smart grid; Paralleling generator systems; Previewing NEC 2017 changes
As brand protection manager for Eaton’s Electrical Sector, Tom Grace oversees counterfeit awareness...
Amara Rozgus is chief editor and content manager of Consulting-Specifier Engineer magazine.
IEEE power industry experts bring their combined experience in the electrical power industry...
Michael Heinsdorf, P.E., LEED AP, CDT is an Engineering Specification Writer at ARCOM MasterSpec.
Automation Engineer; Wood Group
System Integrator; Cross Integrated Systems Group
Fire & Life Safety Engineer; Technip USA Inc.
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me