ASHRAE 188P open for public comment

ASHRAE 188P is open for a public review. Standard 188P, Prevention of Legionellosis Associated with Building Water Systems, specifies what must be done to control the spread of legionellosis.

01/31/2013


Standard 188P, Prevention of Legionellosis Associated with Building Water Systems, specifies what must be done to control the spread of legionellosis. The standard helps facility managers/owners understand how to apply the available information on Legionella effectively in order to prevent cases of legionellosis associated with building water systems.

The proposed standard underwent an earlier public review in June 2011 and is currently open for a third public review until March 11, 2013. For more information, visit www.ashrae.org/publicreviews.

William McCoy said the committee received more than 150 comments during the 2011 review. The input helped the committee in clarifying many aspects of the standards. Changes being proposed to the third review based on that input, include:

  • Clarifications made to definitions in Section 3, Definition of Terms and a new term was defined.
  • Clarifications made to Section 5, Risk Characterization. Those changes were substantive because building characteristics were reorganized into two subsections for clarity, subsections 5.2 and 5.3.
  • Reorganization of Table 1, Determining Preventative Measures Required for Buildings. The improvements reference two subsections of Section 5 (Sec 5.2 and 5.3).
  • Creation of a new subsection, 7.4, Water System Treatment and Management Program, in Section 7. Commenters indicated there should be specifications for a “water system treatment and management program” for buildings with none of the risk characteristics (now listed in Sec 5.2) but with any of the equipment specified (now listed in Sec 5.3),.
  • Clarifications to Section 8 regarding wording, references, cited regulations and informative notes.

Compliance with the standard requires facility managers/owners to formally take responsibility for controlling Legionella in their building water systems, while at the same time acts as a defense against accusations of negligence in those cases which are caused by the hazard from unknown sources.

Standard 188P also covers the potable water system in buildings, which are not treated as often as cooling towers, and will hold facility managers/owners accountable for properly managing the entire building water system both potable and utility water.

The standard differs from ASHRAE Guideline 12, Minimizing the Risk of Legionellosis Associated with Building Water Systems, in that while the guideline gives recommendations about how to treat various building water systems, the standard specifies the practice of exactly what must be done with all those recommendations.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity
About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.