Analyzing, tracking process hazards

Regulatory compliance is driving industry to provide more complete information concerning its manufacturing processes and systems partially because many process industries either use hazardous feedstock or produce hazardous materials. To ensure safe operation of these facilities, OSHA Process Safety Management (PSM) rules (29 CFR 1910.

Staff

01/01/1970


Regulatory compliance is driving industry to provide more complete information concerning its manufacturing processes and systems partially because many process industries either use hazardous feedstock or produce hazardous materials. To ensure safe operation of these facilities, OSHA Process Safety Management (PSM) rules (29 CFR 1910.119) mandate documentation of the process and its associated control system design.

It is vital that the control development team be an integral part of a PSM documentation effort, recording how the control system manages a process and the failure modes of the system. All possible control failure schemes must be considered as part of the completed project—a difficult task at best. Therefore, control system plans need to be part of the initial Process Hazard Analysis (PHA) in addition to being implemented and maintained under Management of Change (MOC) program for the process.

Additional help available

To assist, hazard analysis guidelines are available from the American Institute of Chemical Engineers Center for Chemical Process Safety (New York, N.Y.). However, to augment these existing resources, Dyadem International Ltd. (Markham, Ontario, Canada) has developed PHA-Pro 5, a software package designed to support Process Hazard Analysis, capturing all required process and control system data. Areas tracked in the software include:

  • PHA team members and their attendance at PHA sessions;

  • Process units and their functions;

  • Safety and environmental hazards associated with each unit, including hazard severity;

  • Installation, operation, and maintainability issues for all control systems;

  • PHA recommendations for safety improvement;

  • All piping and instrumentation drawings (P&IDs); and,

  • Operational procedures.

The program supports all common types of PHA methodologies and comes with basic question libraries for "What if" and Hazard and Operability studies. In addition, these libraries can be edited to create a site-specific template for analysis. This is particularly useful for creating a custom node template for the control system that is in generic form and not addressed in the MOC library.

Another valuable feature for the individual responsible for maintaining the control system is the ability to integrate PHA and MOC activities into one database. A single database places the history of control system decisions in the same tracking environment for implementing changes. Thus, even when original team members are unavailable, the logic behind all control system design decisions and revisions is available in a central location. Because analysis of a process to meet OSHA regulations typically requires several meetings, and a considerable time investment, process developers can use this custom database application to protect against data loss, guarding against the need for data reentry or repeating earlier investigative meetings.

Important security

Because the data are also used for MOC analysis, all database information needs to be secure for the life of the process. To prevent loss of data, the PHA-Pro package has multiple levels of protection specifically intended to provide data integrity.

This review is based upon version 5.2.1.29 of the PHA-Pro 5 package, www.dyadem.com.

Contributing Editor, Tracy J. Coates P.E. is a consulting engineer at PCE Engineering, Johnson City, Tenn.

For more information on PHA-Pro 5, circle 345 or go online at www.controleng.com/freeinfo.





No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
40 under 40
Integrating lighting, HVAC systems; Use building energy modeling software to balance lighting and HVAC systems
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity
About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.