2012 Edition of the National Electricity Safety Code available

Among the changes for the NESC's 2012 edition include standards to help design, install, operate, and maintain electrical supply and communication lines and associated equipment.

09/16/2011


IEEE announced the availability of the National Electrical Safety Code (NESC) – 2012 Edition. The NESC provides practical guidance to help safeguard employees and the public when electrical supply and communications lines are installed operated and maintained, including overhead and underground electrical supply lines, telephone or cable and TV lines, and signal and power installations for railroads.

Some of the revisions in the NESC 2012 edition include:

  • Scope, application and definition rules extensively revised to provide clarification improvements, particularly with respect to whether the NESC or the National Electrical Code (NEC) (NFPA 70) applies in certain situations;
  • Grounding rules added specificity to the methods to be used to help achieve effective grounding connections;
  • Electrical supply stations rules added options for improved protection of energized parts from interference by activities outside the stations and for guarding inside the stations. The overhead general rules revised requirements for inspections and for facilities to be grounded or insulated;
  • Underground rules revised the inspection rules and clarified requirements for direct-buried cables and conduits not part of a conduit system;
  • Work rules added options for determining appropriate arc ratings for apparel to be worn while working on energized lines, including a new Section on Clothing requirements for <1000 Volts and added maximum clearing times allowed for specified apparel arc ratings, and;
  • Revised the minimum approach distances (MADs) to meet the requirements of IEEE 516-2009, and revised specification for the location of employee protective grounds.

More details of the 2012 revisions can be found here.



No comments
Consulting-Specifying Engineer's Product of the Year (POY) contest is the premier award for new products in the HVAC, fire, electrical, and...
Consulting-Specifying Engineer magazine is dedicated to encouraging and recognizing the most talented young individuals...
The MEP Giants program lists the top mechanical, electrical, plumbing, and fire protection engineering firms in the United States.
Integrating lighting, HVAC systems, Energy codes and lighting, BIM and fire protection engineering
Engineering hospital electrical systems, Boilers and boiler systems, Building envelope best practices
Hospital indoor air quality, ASHRAE 90.1 update, Specifying piping materials, Integrated project delivery
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Consulting-Specifying Engineer case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Preventing arc flash, Backup power fuel choices, power for high-tech facilities
Using BIM in electrical power design; Closed-transition transfer; Medium-voltage distribution; Diesel emission regulations; Increasing emergency power capacity
About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.