Staff -- Consulting-Specifying Engineer, 3/1/2003

Networking PC cabinet can house remote computers and peripherals used for data entry or LAN or WAN access. It features welded steel construction, a flush-mounted safety glass window and flush doors and is divided into three lockable sections for controlled access. A 6-in. exhaust fan is optional. (Type 1 by Hoffman)

Radiant heating system uses warm water to transfer heat from its production point to areas of need. It employs cross-linked polyethylene (PEX) tubing and can be installed in walls, ceilings and floors. It controls the mean radiant temperature, raising the temperature of objects in a room by means of radiation, convection and conduction. (Radiant Heating System by Zurn Plumbing Products Group)

Induced-draft gas water heater can be vented up to 75 ft. horizontally or vertically using 3-in. PVC, ABS or CPVC pipe. With 2-in. plastic pipe, the venting distance can be extended to 32 ft. Available in 40- and 50-gal. models with inputs of 40,000 BTU/hr., the heater obtains energy efficiency ratings of .64 and .65, respectively. Both models use 2.5-in.-thick R-20 foam insulation to reduce heat loss. (PowerVent 2 by Rheem)

CD-ROM approval guide lists more than 45,000 fire-protection, electrical, and building equipment materials and services, including thousands of new and revised listings. Products are listed by their trade name and include the manufacturer's name and address, catalog numbers and application and use information. The guide is also available in printed format. (2003 Approval Guide by FM Approvals)

Radio frequency modem enables wireless communication between remote I/O devices. It can operate as a master, slave or repeater and support RS-232/4232/485 communication. Data rates of up to 115.2 Kbps can be achieved with full-duplex asynchronous communication, and half-duplex is also supported. An assortment of antennae, cables and other accessories are available. (BusWorks OS2400-485 by Acromag, Inc.)

Hubs offer USB 2.0 speed and connectivity to existing USB 1.0 and 1.1 devices. They come with drivers, USB cables and power supplies and can be daisy-chained to connect up to 127 USB devices. (USBH 3204 by CyberResearch, Inc.)

Stagger strip lighting fixtures are adjustable and feature integral ballasts. They expand by 50% of their length, and once they are installed, a locking mechanism keeps the sliding section secure. The fixtures are available in standard 2-, 3- and 4-ft. lengths, a 2.7-in. width and in either T5 or T8 lamp sizes. Optional symmetrical or asymmetrical reflectors are also available. (AST Series by LaMar Lighting)

Desiccant dehumidifier is designed for several applications, including prevention of condensation, bacterial growth, corrosion and moisture regain, as well as product drying. Features include round collar duct connections at all inlets and outlets, an extruded anodized aluminum frame, large diameter and inorganic desiccant media rotors, and backward-inclined motorized impellers. (Dry3 Compact Series by Bry-Air)

Lighting fixtures for health-care facilities provide four separate indirect and direct lighting functions—room ambient, patient reading, physician exam and optional nurse's night light. Constructed from 20-gauge cold-rolled steel and coated with a 90% reflectance finish, the fixture's illumination is provided by six 40-watt biax lamps. (Multi-Med by Alkco)

Mechanical interlock devices combine a pin-and-sleeve receptacle with a safety disconnect switch into a single unit. All models include a factory-installed auxiliary contact for remote line management and power monitoring. Space is also provided for an additional auxiliary contact. The units feature wiring space for drip loops and are supplied with a pre-winded grounding plate connected to the liquid-tight hub. (IEC 309-1 and 302-2 PowerSwitch by Leviton)

Fire alarm control panel features auto-programming capabilities and includes an integral remote upload/download communicator, which allows for reporting of all system activity to a remote monitoring location. (MS-9200UD by Fire-Lite Alarms)

Variable refrigerant flow zoning (VRFZ) system features inverter technology and simultaneous heating and cooling. A proprietary control system ties together the outdoor unit, branch circuit controller, indoor units, and remote and central controllers. Two outdoor models are offered: an 80,000-BTU/h unit with up to 15 connectable indoor units; and a 100,000-BTU/h unit with up to 16 connectable indoor units. Both models can be ducted or ductless. Indoor models are available in wall-mounted, ceiling-recessed and concealed-ducted models. (CITY MULTI R2 Series by Mitsubishi Electric)

Cabling system is rated at 600V. The rating offers installers the ability to route both trunk (thick) and drop (thin) cabling adjacent to 600V-rated power cabling for tray or raceway use. Various connectors can be configured using this cable option, including male and female connectors and receptacles. (Brad Harrison DeviceNet by Woodhead Connectivity)

Corrections: In CSE 01/03 p.51, a photo depicting SE4 Series security lighting from Ruud Lighting appeared upside down. Also, in CSE 02/03 p. 58, product photos were inadvertently switched. The top photo on the page shows SpecMate L from Wiremold. The middle photo is a flexible wire duct from Panduit. We regret the errors.

 

R.S. Means Technology Cost Breakdown: Chillers

Editor's Note: The following cost breakdown on packaged water chillers is provided by the R.S. Means division of Reed Construction Data and is intended as a quick reference for a range of equipment sizes and ratings. For more info, visit: www.rsmeans.com

Rating (Tons)Daily Crew OutputLabor HoursUnitMatl.LaborEqup.Total
Absorption Water Chillers
Steam or hot water, water-cooled 1000.13240Ea.115,5008,600 124,100
8500.08385 343,00013,800 356,800
1,6600.07477 635,50017,100 652,600
For two-stage unit, add: 80%25%
Gas-fired, air-cooled 31.3012.3 6,025415 6,440
50.6026.6 7,050905 7,955
100.4040 16,9001,350 18,250
Water-cooled duplex 1000.13246 122,0008,825 130,825
5000.10329 319,00011,800 330,800
1,0000.08421 631,00015, 100 646,100
Centrifugal/Screw/Reciprocal Water Chillers
Centrifugal liquid chiller, water-cooled not including water tower, open drive2,0000.07477 521,50017,100 538,600
Screw, liquid chiller, air-cooled, insul. evaporator 1300.14228 58,5008,200 66,700
1800.13250 81,0008.975 89,975
3200.12275 128,0009,900 137,900
Packaged unit, water-cooled, not incl. tower 800.14223 33,0008,025 41,025
2000.13251 64,0009,025 73,025
3500.12275 106,5009,900 116,400
Centrifugal, packaged unit, water-cooled, not including tower 4000.11283 118,50010,200 128,700
9000.09359 276,00012,900 288,900
1,9000.07470 583,00016,900 599,900
Reciprocating, packaged with integral air-cooled 200.3494.95 27,3003,400 30,700
1000.25129 99,5004,625 104,125
3900.18172 352,0006,200 358,200
Source: R.S. Means

Email
Print
Reprint
Learn RSS

Talkback

We would love your feedback!

Post a comment

» VIEW ALL TALKBACK THREADS

Related Content

Related Content

 

By This Author



SPONSORED LINKS

 
Advertisement
Sponsored Links

More Content

  • Blogs
  • Podcast

Blogs


Sorry, no blogs are active for this topic.

» VIEW ALL BLOGS RSS

Podcast

Senior Editor Amara Rozgus (pictured) speaks with John Suzukida, PE, president of Lanex Consulting LLC, Shoreview, Minn. This conversation is about the role of electricity in the future and zoned heating and cooling.
Cooling People, Not Buildings with John Suzukida, PE
Senior Editor Amara Rozgus (pictured) speaks with John Suzukida, PE, president of Lanex Consulting LLC, Shoreview, Minn. This conversation is about the role of electricity in the future and zoned heating and cooling.
Listen Now | Download MP3 | Subscribe
» VIEW ALL PODCASTS Subscribe Now to HVAC & Building Automation and never miss an episode
Advertisements





NEWSLETTERS
Plug in and get the latest CSE news, trends and industry updates delivered directly to your inbox!

Green Scene
CSE Codes & Standards
CSE NewsWatch
CSE Fire and Life Safety Solutions
CSE Business of Engineering Management Report
CSE Electrical Solutions
CSE HVAC Solutions
Pure Power
CSE Product Showcase
©2008 Reed Business Information, a division of Reed Elsevier Inc. All rights reserved.
Use of this Web site is subject to its Terms of Use | Privacy Policy
Please visit these other Reed Business sites