R.S. Means Technology Cost Breakdown: Heating Boilers

Staff -- Consulting-Specifying Engineer, 2/1/2003

Editor's Note: The following cost breakdown on heating boilers, provided by the R.S. Means division of Reed Construction Data, is intended as a quick reference for the most commonly specified system equipment types. For more info, visit: www.rsmeans.com

Cast iron section boilers may be assembled in place or shipped to the site as a completely assembled combustion package. These units can be made larger on site by adding intermediate sections.

Steel boilers are usually shipped to the site completely assembled. Large steel boilers may be shipped in segments for field assembly and testing.

Heating boilers are rated by their hourly output, expressed in British thermal units (BTU). The equipment considered in the cost breakdown above is a representative mid-range sample, rated in "thousand BTUs per hr." (MBh).

The output available at the boiler supply nozzle is referred to as the gross output. The gross output in BTU per hr. divided by 33,475 yields the boiler's horsepower rating. The net rating of a boiler is the gross output less allowances for the piping tax and the pickup load. The net load should match the building heating load.

Due to the high cost of fuel, efficiency of operation is a prime consideration when selecting boiler units. Because of this, recent innovations in manufacturing have led to more compact and efficient boilers.

The U.S. Dept. of Energy provides test procedures to compare annual fuel utilization efficiency (AFUE). Manufacturers today are claiming close to 90% efficiency, a result of better insulation, heat extractors, intermittent ignitions, induced draft and automatic draft dampers.

R.S. Means Technology Cost Breakdown: Heating Boilers
Rating (MBh)Daily Crew OutputLabor HoursUnitMatl.LaborEqup.Total
Electric, ASME, standard controls and trim
Steam7,9840.16200Ea.48,9007,150 56,050
Hot Water8,1910.25128 42,0004,575 46,575
Gas-fired, natural or propane, standard controls
Cast iron with insulated jacket
Steam, gross output6,9700.10320 58,00011,500 69,500
Hot water, gross output6,9700.09359 59,00012,900 71,900
Steel insulating jacket
Steam, not including burner, gross output7,2000.18177 43,3006,375 49,675
Hot water, burner and one control valves3,0000.15160 32,5005,625 38,125
Gas/Oil, combination with burners and controls
Cast iron with insulated jacket
Steam, gross output6,9700.09372 62,00013,300 75,300
Hot water, gross output7,1300.08385 51,50013,800 65,300
Steel, insulated jacket, skid base, tubeless
Steam, 15 psi, gross output8,8700.09336 55,50012,100 67,600
Steam, 150 psi, gross output2,5110.17141 27,8004,950 32,750
Hot water, gross output3,1500.16146 40,5005,125 45,625
Oil-fired, standard controls, flame-retention burner
Cast iron, with insulated flush jacket
Steam, gross output6,9700.09363 59,00013,000 72,000
Hot water (same price as steam; for tankless coil in smaller sizes, add 15%
Steel, insulated jacket, burner
Steam, full water leg const, gross output2,4000.19125 19,2004,400 23,600
Hot water, gross output3,1500.13184 18,2006,475 24,675
Packaged Scotch Marine, steam or hot water
Packaged fire tube, #2 oil, gross output
Steam, 15 psi8,3750.14231 52,5008.325 60,825
Steam, 150 psi6,7000.14223 57,0008,025 65,025
Source: R.S. Means

Email
Print
Reprint
Learn RSS

Talkback

We would love your feedback!

Post a comment

» VIEW ALL TALKBACK THREADS

Related Content

Related Content

 

By This Author



SPONSORED LINKS

 
Advertisement
Sponsored Links

More Content

  • Blogs
  • Podcast

Blogs


Sorry, no blogs are active for this topic.

» VIEW ALL BLOGS RSS

Podcast

Senior Editor Amara Rozgus (pictured) speaks with John Suzukida, PE, president of Lanex Consulting LLC, Shoreview, Minn. This conversation is about the role of electricity in the future and zoned heating and cooling.
Cooling People, Not Buildings with John Suzukida, PE
Senior Editor Amara Rozgus (pictured) speaks with John Suzukida, PE, president of Lanex Consulting LLC, Shoreview, Minn. This conversation is about the role of electricity in the future and zoned heating and cooling.
Listen Now | Download MP3 | Subscribe
» VIEW ALL PODCASTS Subscribe Now to HVAC & Building Automation and never miss an episode
Advertisements





NEWSLETTERS
Plug in and get the latest CSE news, trends and industry updates delivered directly to your inbox!

Green Scene
CSE Codes & Standards
CSE NewsWatch
CSE Fire and Life Safety Solutions
CSE Business of Engineering Management Report
CSE Electrical Solutions
CSE HVAC Solutions
Pure Power
CSE Product Showcase
©2008 Reed Business Information, a division of Reed Elsevier Inc. All rights reserved.
Use of this Web site is subject to its Terms of Use | Privacy Policy
Please visit these other Reed Business sites